Home | Products | Electrical Equipment | Socomec | Mounting and Cabling Systems | Mounting and Cabling Accessories

Mounting and Cabling Accessories

The SOCOMEC copper bars make it possible to carry out main or distribution busbars.

The range Solid bars

  • Thickness: 4, 5 and 10 mm.
  • Width: 20 to 160 mm.
  • Length: 1750, 2900, 5800 mm.

Pre-punched bars

  • Thickness: 5 and 10 mm.
  • Width: 25 to 125 mm.
  • Length: 1750 mm.

Pre-punched and threaded bars

  • Thickness: 5 mm.
  • Width: 15 to 32 mm.
  • Length: 990 mm.

Earth / Neutral connection

  • Angle profile for Earth / Neutral

connection, L = 1750 mm.

  • Earth bar, L = 470 mm and L = 120 mm.

General characteristics of copper

  • Material: electrolytic copper Cu-ETP (Cu/A1).
  • State: hammer-hardened 1/2 hard (H12).
  • Maximum resistivity: 0.017241 Ωmm2/m at 20°C.

SOCOMEC flexible copper bars are mainly used to make the links between series of distribution bus bars and the disconnection devices.

Conformity to standards

  • VDE 207 Y16 VDE 207 YM4
  • BS 6746 DIN 40050
  • NF A 51-050

General characteristics

  • Width of 9 to 100 mm.
  • Thickness of 0.8 to 1 mm.
  • Length of 2 m.

Ease of positioning

  • Reduced space covering.
  • Wide flexibility of the bus bar.
  • Time saving by elimination of terminals

and their clinching.

Increased safety by the elimination of connections

  • Better behaviour in short-circuits.
  • Decrease of heating ponts.
  • Better protection of people

SOCOMEC insulating busbar supports allow the fixation of a copper or aluminium bar or busbar.

Conformity to standards

  • IEC 60439-1
  • IEC 60865-1

Approvals and certifications(1)

  • KEMA
  • Lloyd's Register of Shipping
  • ASEFA/LCIE

(1) According to supports.

General characteristics Insulators

  • Polyester without halogene.
  • UL94 VO self-extingishable.
  • Colour: red RAL 3002.
  • Operating temperature from - 40°C to + 130°C.
  • Deformation under load temperature (ASTM D643): > 200°C.
  • Dielectric constant (ASTM D150): 4/5.
  • Arc resistance (ASTM D495): > 180 s.
  • Water absorption (ASTM D570):

< 0.3 %.

Busbar supports

  • High dielectric resistance.
  • High mechanical strength.
  • Amagnetism of assembly parts.
  • High resistance to damp heat (originally "tropicalized").

Stair type supports

  • Thermoplastic material.
  • Self-extinguishing VO.
  • Insulating voltage: 1000 V.


Overview Mounting and Cabling Accessories:

Download file (295 KB)


For more information, download this file

 1.  Rigid Copper Bars 436 KB
 2.  Insulated Flexible Copper Bars 421
KB
 3.  Busbar Support 4,36 MB
 4.  Mechanical Systems Software 348 KB
 5.  Distribution Blocks 1,00 MB
 6.  Power Terminals 355 KB
 7.  BLOCAL Aluminium Systems 185 KB
 8.  Mounting Rails and Profiles 153 KB